0%

Cement drying times

Drying times of various cements, also known as the "Curing Time" generally takes a matter of minutes when assemblying a pipe system, allowing joints to be easily handled. It is however important to note that although the joints may set quickly, the system may require long curing times depending on the material type and pipeline size before it can be used under pressure.

Please note that environmental factors play a large role in curing times. Joints cure faster in drier, warmer temperatures. Details listed below are based on ambient tempertaures (20° Celcius)

 
UNI-100® PVC-u Cement
PIPE DIAMETER: Up to 2" or 16 - 63mm 2 1/2" - 4" or 75mm - 110mm 5" and above or 125mm - 315mm
Temp max 10 bar max 16 bar max 10 bar max 16 bar max 10 bar max 16 bar
5 - 10°C 4 h 8 h 8 h 16 h 16 h 32 h
> 10°C 2 h 4 h 4 h 8 h 8 h 16 h
 

These times are applicable to UNI-100® Griffon cement.
Solvent cement setting times are given for guidance only and can vary depending on a number of factors.

 
UNI-100 XT® PVC-u Cement
PIPE DIAMETER: Up to 2" or 16 - 63mm 2 1/2" - 4" or 75mm - 110mm 5" and above or 125mm - 400mm
Temp 5 bar 10 bar 16 bar 5 bar 10 bar 16 bar 5 bar 10 bar
5 - 10°C 6 h 12 h 24 h 12 h 24 h 48 h 36 h 72 h
> 10°C 2 h 4 h 8 h 4 h 8 h 16 h 12 h 24 h
 

These times are applicable to UNI-100 XT® Griffon cement.
Solvent cement setting times are given for guidance only and can vary depending on a number of factors.

 
UNI-100 GT® PVC-u Cement
PIPE DIAMETER: Up to 2" or 16 - 63mm 2 1/2" - 4" or 75mm - 110mm 5" and above or 125mm - 315mm 5" and above or 125mm - 315mm
Temp 10 bar 16 bar 10 bar 16 bar 10 bar 16 bar 10 bar 10 bar
5 - 10°C 8 h 16 h 16 h 32 h 32 h 64 h 64 h 128 h
> 10°C 4 h 8 h 8 h 16 h 16 h 32 h 32 h 64 h
> 25°C 2 h 4 h 4 h 8 h 8 h 16 h 16 h 32 h
 

These times are applicable to UNI-100 GT® Griffon cement.
Solvent cement setting times are given for guidance only and can vary depending on a number of factors.

 
WDF-05® PVC-u Cement
PIPE DIAMETER: Up to 1 1/2" or 16mm - 50mm 2" - 4" or 63mm - 110mm 5" or 125mm - 160mm
Temp 5 bar 10 bar 16 bar 5 bar 10 bar 16 bar 5 bar 10 bar 16 bar
5 - 15°C 30 min 1 h 4 h 1 h 2 h 8 h 4 h 16 h 32 h
> 15°C 15 min 30 min 2 h 30 min 1 h 4h 2h 8h 16h
 

These times are applicable to WDF-05® Griffon cement.
Solvent cement setting times are given for guidance only and can vary depending on a number of factors.

 

ABS cement drying times

B-25® ABS Cement
PIPE DIAMETER: Up to 2" or 16mm - 63mm 2 1/2" - 6" or 75mm - 160mm 16mm - 160mm 200mm - 315mm
Temp ≤ 10 bar ≤ 15 bar ≤ 10 bar ≤ 15 bar ≤ 10 bar ≤ 15 bar No Pressure
0 - 5°C 12 h 24 h 18 h 32 h 96 h 120 h 4 h 8 h
5 - 15°C 8 h 16 h 12 h 24 h 72 h 96 h 3 h 8 h
> 15°C 4 h 8 h 6 h 16 h 48 h 72 h 1 h 1 h
 

These times are applicable to B-25® Griffon cement.
Solvent cement setting times are given for guidance only and can vary depending on a number of factors.

 

Cement Usage Recommendations

Nominal Bore Number of Joints Type / Size of Brush Number of People
3/8" - 1/2" or 16mm - 20mm 1300 4mm round 1
3/4" - 1" or 25mm - 32mm 650 8mm round 1
1 1/4"" - 2" or 40mm - 63mm 160 1" Flat 1
2 1/2" or 75mm 90 2" Flat 1
3" or 90mm 70 2" Flat 2
4" or 110mm 30 3" Flat 2
5" - 6" or 140mm - 160mm 20 3" Flat 3
8" or 225mm 12 3" Flat 3
10" or 250mm - 280mm 8 3" Flat 3
12" or 315mm 4 3" Flat 3
 

What size Glue Brush?

Pipe Size Brush Type / Size
3/8" to 1/2" 4mm Round
3/4" to 1" 8mm Round
1 1/4" to 2" 1/2" to 1" Flat
2 1/2" to 4" 2" Flat
5" to 8" 3" Flat